Descripción
The MCS-103-1 is an enclosed control complete with a cover and mounting provisions. A brake and clutch may be operated separately with this control – or up to four units, two at a time. The external wiring is connected to the terminal strip located behind the cover.
•UL
• Can be used with electrically released brakes Torque control for one 90 VDC clutch or brake
• Operates up to four units, two on at a time
• Easy-to-install. Compact. 120 VAC input
• Convenient terminal strip behind an easy-to-remove cover
Specifications
MCS-103-1
Part No. 6010-448-002
Input 120 VAC, 50/60 Hz
Output 1.25 Amp
90 V full wave rectified for one unit and adjustable from
0-90 volts full wave rectified for second unit
Circuit Protection Fused 1.5 Amp, 250 V
Ambient Temperature -20° to 113°F (-29° to 45°C)
Maximum Cycle Rate Limited by the clutch or brake and will vary with application.
Mounting Mounting centers 5-1/2” wide, 3” high. Knockouts for 1/2” conduit
External Switches Double pole, double throw maintained contact. Minimum contact rating: 10 Amp, 28 VDC resistive or 10 Amp, 120 VAC inductive. Contact ratings given will operate all Warner Electric brake and clutch units. However, switches with ratings less than those given may be used with fractional horsepower units provided the rating is equal to or greater than the coil current.